WUFI® Pro (1D) evaluates heat and moisture transport through typical wall, roof, and floor assemblies, helping assess their long-term hygrothermal performance.
WUFI® 2D extends the analysis to complex two-dimensional details—such as corners, junctions, transitions, and thermal bridges—where geometry influences heat and moisture behavior.
Assessment of moisture accumulation, condensation risk, drying potential, and mold-growth risk under project-specific, real-world weather conditions. Hygrothermal simulations incorporate climate data representative of the project location, with hygrothermal risk evaluated using ASHRAE Standard 160 criteria to support durable and moisture-resilient building enclosures.
Evaluation of building enclosure thermal performance through R-value and U-factor calculations, with analysis of thermal bridges at critical details and transitions to identify heat-loss paths and support energy-efficient, high-performing enclosure design.
Whether you need support during design, construction, or a forensic investigation, tell us about your building enclosure needs. We’ll be happy to discuss your project and provide a free quote.